best wood WALL 180 Plaster base board for exterior use
WALL 180 is a pressure-resistant, plasterable wood fibre insulation board for installation on timber stud constructions in exterior wall areas.
Advantages:
- Excellent thermal conductivity value
- Good heat protection in summer and optimal thermal insulation in winter
- Improves sound insulation: wood fibre insulation boards are very good sound insulators, the higher the raw density the better the sound insulating effect
- Hydrophobic throughout
- Open to diffusion and therefore moisture-regulating
- Easy installation - secured by our processing guidelines ETICS
- Hardly any waste due to the fact that the wood fibre insulation boards can be used on both sides
- Completely recyclable
-
0.043 [W/mK]
Nominal value of thermal conductivity λD according to DIN EN 13171
-
0.043 [W/mK]
Declared thermal conductivity λD according to SIA 279 (Switzerland)
-
0.045 [W/mK]
Rated value of thermal conductivity λB according to DIN 4108-4
-
180 [kg/m³]
Density
Fields of application
- Exterior masonry and solid wood walls
- Can be plastered directly
Fields of application according to DIN 4108-10
DEO-ds, WAB-ds, WAP-zh, WZ, WH, WI-zg, WTR
Delivery formats
-
Design
- Tongue and groove
- Square edge
Format (mm) | ||||||
580 x 1500 | 580 x 2000 | 580 x 2500 | 600 x 1500 | 600 x 2000 | 600 x 2500 | |
20 | ||||||
40 | ||||||
60 | ||||||
80 | ||||||
100 | ||||||
120 | ||||||
140 | ||||||
160 | ||||||
Thickness (mm) |
Technical data
Denomination of insulation board | WF-EN 13171-T5-DS(70,-)3-CS(10\Y)150-TR30-WS1,0-MU3-AFr100 |
Standard | EN13171 |
ETA/design approval | ETA-16/0997; aBG Z-33.84-1674 |
Density | 180 [kg/m³] |
Nominal value of thermal conductivity λD | 0.043 [W/(mK)] |
Rated value of thermal conductivity λB | 0.045 [W/(mK)] |
Reaction to fire according to DIN EN 13501-1 | E |
Construction material class according to DIN 4102-1 | B2 |
Full declaration | Wood fibers, PMDI gluing, paraffin |
Production process | Dry process |
Compressive stress at 10% compression | ≥ 150 [kPa] |
Tensile strength perpendicular to the plane of the board | ≥ 30 [kPa] |
Modulus of elasticity E(d) | ≥ 2,5 [N/mm2] |
Water vapor diffusion resistance μ | 3 |
Linear flow resistance | > 100 [kPa·s/m²] |
Short time water absorption | < 1.0 [kg/m²] |
Specific heat capacity | 2100 [J/(kgK)] |
Waste code according to AVV | 030105, 170201 |
Accessories
Here you will find popular accessories for this product.
Suitable accessories